top of page
Alex-L nd yag 사본_1.jpg

Q10 ensures significant power output for pigment procedures, maintaining consistent performance across a wide treatment area. The even distribution of energy improves safety and effectiveness, reducing the likelihood of skin thermal injury while selectively removing pigments in the dermis. Moreover, the PTP mode is designed to offer a more comfortable experience with reduced pain and faster regeneration compared to the single-pulse mode. In addition to the advantages of Q10, the enhanced Q10 PREMIUM model includes an additional long-pulsed mode that can be used for both hair removal and the treatment of vascular lesions.

Flat top-hat beam profileBoth Q10 and Q10 PREMIUM exhibit a flat top-hat beam profile, ensuring uniform and consistent energy delivery to the target area.

beam profile -1.png
beam profile -2.png
beam profile - 3.png

Dual-pulse with less skin damage (PTP)

PTP Pulse.png
Single pulse.png

By employing the PTP mode, both Q10 and Q10 PREMIUM have the capability to emit consecutive dual pulses at a maximum energy of 1.8 J. In contrast to the single-pulse mode, this configuration allows for the delivery of twice the number of pulses, each with nearly half the energy per pulse. The advantage lies in its ability to minimize treatment discomfort, as it avoids damaging normal surrounding skin tissues, a drawback associated with the single-pulse mode. Consequently, the reduced likelihood of side effects is achieved without compromising clinical results, and in most of cases, may even yield better clinical outcomes.The transmission of a high energy level (e.g. 1.8J) in a single instance has the potential to harm the skin. Due to the fact physicians tend to administer less energy to the skin compared to PTP, therefore the photothermal effect necessary for collagen regeneration may not reach a sufficient level.In PTP mode, double the number of laser beams are administered, providing increased energy and vibration to effectively target and destroy melanin pigment. Additionally, this mode ensures that the photothermal effect required for collagen regeneration reaches a sufficient level.

1064 nm long-pulsed mode for more indications*In addition to the advantages of Q10, the enhanced Q10 PREMIUM model includes an additional long-pulsed mode that can be used for both hair removal and the treatment of vascular lesions.

Long pulse 1064.png
Handpieces_edited.png

Various handpiecesWith the diverse selection of handpieces provided by Q10 and Q10 PREMIUM, physicians can administer treatments to patients at the optimal settings.

Zoom HP
(2-10mm)

Zoom HP
(11-15mm)

Fraxtional
HP

585 HP

595 HP

650 HP

660 HP

Indication

Q10 Q10 PREMIUM - indication_edited.png

Technical specification

Q10 PREMIUM - Specification_edited.png

1303ho,Baeksang Startower 2nd, 165 GasanDigital2ro, Geumcheon-gu  Seoul Korea 

Tel : +827046429154         Fax : +8227119154       

ARUMMEDI, All rights reserved.

bottom of page